This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| admin:datacenter [2019/05/30 19:31] peppe | admin:datacenter [2021/09/15 13:22] (current) peppe [Table] | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ===== Data Center ===== | ===== Data Center ===== | ||
| - | ==== Rack (top to bottom) ==== | + | ==== Rack #1 (top to bottom) ==== | 
| {{: | {{: | ||
| Line 46: | Line 46: | ||
| ^ Name   ^ Services | ^ Name   ^ Services | ||
| | FIXME | | | | FIXME | | | ||
| + | |||
| + | 3x iSCSI disks for uranus: | ||
| + | Port #3 to EMC VNXe3100 SPA port #3 | ||
| + | Port #4 to EMC VNXe3100 SPB port #3 | ||
| ---- | ---- | ||
| Line 95: | Line 99: | ||
| ==== EMC VNXe3100 (NAS) ==== | ==== EMC VNXe3100 (NAS) ==== | ||
| + | |||
| + | 8GB RAM, 18x1TB NL-SAS, 3xRAID6(6-disk) groups, 3x3.7TB usable. | ||
| + | |||
| + | Serial console to SPA @9600 from Lazarus FreeBSD guest ("tip com1" | ||
| + | |||
| + | Restart failed management services: | ||
| + | # svc_restart_service restart MGMT | ||
| + | |||
| + | Check peer SP: | ||
| + | # ping peer | ||
| + | |||
| + | Shutdown: | ||
| + | # svc_shutdown --system-halt | ||
| + |  | ||
| + | |||
| + | Diag: | ||
| + | # svc_diag --state=basic | ||
| + | # svc_diag --state=software | ||
| + | # svc_sysstatus | ||
| FIXME Change UTP redundant cables to ESXI #2 (iSCSI). | FIXME Change UTP redundant cables to ESXI #2 (iSCSI). | ||
| Line 210: | Line 233: | ||
| ==== Hp Procurve 2848 J4904A Switch ==== | ==== Hp Procurve 2848 J4904A Switch ==== | ||
| + | |||
| + | IP: 10.1.2.253 | ||
| {{tablelayout? | {{tablelayout? | ||
| Line 269: | Line 294: | ||
| ==== Cisco SG200-26 Gigabit Smart Switch ==== | ==== Cisco SG200-26 Gigabit Smart Switch ==== | ||
| + | |||
| + | IP: 10.1.2.254 | ||
| {{tablelayout? | {{tablelayout? | ||
| Line 288: | Line 315: | ||
| ^  15 | ^  15 | ||
| ^  16 | ^  16 | ||
| - | ^  17 | + | ^  17 | 
| ^  18 | ^  18 | ||
| ^  19 | ^  19 | ||
| Line 345: | Line 372: | ||
| ---- | ---- | ||
| + | |||
| + | ==== Rack #2 (top to bottom) ==== | ||
| + | |||
| + | === HP Procurve 2680 === | ||
| + | IP: 10.1.2.254 | ||
| + | |||
| ==== Out of rack ==== | ==== Out of rack ==== | ||
| Line 371: | Line 404: | ||
| === Sun Fire v480 (zeus) === | === Sun Fire v480 (zeus) === | ||
| {{tablelayout? | {{tablelayout? | ||
| - | ^ Name ^ old gaia ^ | + | ^ Name ^ old zeus ^ | 
| ^ Services | ^ Services | ||
| ^ OS        | Solaris/ | ^ OS        | Solaris/ | ||
| Line 395: | Line 428: | ||
| ^ Name ^ old gaia ^ | ^ Name ^ old gaia ^ | ||
| ^ Services | ^ Services | ||
| - | ^ OS | -- | | + | ^ OS | ESXi 5.5U3 | | 
| ^ IP | -- | | ^ IP | -- | | ||
| ^ iLO       | 10.1.2.101 | ^ iLO       | 10.1.2.101 | ||
| Line 402: | Line 435: | ||
| ^ Model     | DL380G6 | ^ Model     | DL380G6 | ||
| ^ CPU(s) | ^ CPU(s) | ||
| - | ^ RAM | + | ^ RAM | 
| ^ Storage | ^ Storage | ||
| ^ P/N       | 470065-082 | ^ P/N       | 470065-082 | ||
| ^ S/N       | CZ2047J8R1 | ^ S/N       | CZ2047J8R1 | ||
| - | 3/2018 Decommissioned, | + | 3/2018 Decommissioned, | 
| - | 30/ | + | |
| + | 30/ | ||
| + | {{tablelayout? | ||
| + | ^  J24 | ||
| + | |  0V | ||
| + | | GND | GND | | GND | GND | | ||
| + | | 3V3 | 3V3 | | 3V3 | 3V3 | | ||
| + | | GND | GND | | GND | GND | | ||
| + | |  0V | ||
| + | |||
| + | 3/6/2019 Πιθανό σφάλμα στο cache module του smartarray (462975-001, | ||
| + | |||
| + | |||
| + | 6/6/2019 Εγκατάσταση ESXi 5.5 και ενημέρωση σε 5.5U3 που λειτουργεί σωστά με το cache module (χωρίς μπαταρία). Επιπλέον εγκατάσταση esxui για web πρόσβαση στη διαχείριση. | ||
| + | |||
| + | 13/6/2019 Δίσκοι: | ||
| ---- | ---- | ||